Derby Duck Giant inflatable Riding Duck

Source: Derby Duck Giant inflatable Riding Duck The world-renowned Derby Duck now taking passengers! The classic Derby Duck goes big! Now a pool inflatable that adds cool to your pool and will provide hours of fun for you and your family. Built for fun and seating multiple people. Even makes a great lounger for…

via — null

Posted in Uncategorized | Leave a comment

refurbished arctic hot tub with 1 yr warranty

Refurbished arctic hot tub with 1 yr warranty 3500.00 .

20160125_11170320160125_111644 

comes with new cover choice of color . financing ,installation and delivery available .

2 pump system
1 blower
single light multi-color led
all weather cedar cabinet ready to stain any color with per-miter insulation.

finance 4
call us for viewing today

Posted in Hot tub repair and sales financing cochrane, hot tub repair Cochrane 587-333-2386, refurbished hot tub for sale, Uncategorized | Tagged | Leave a comment

Coupon towards new tub purchases

coupon western new tub

finance 4

Posted in Hot tub repair and sales financing cochrane | Tagged | Leave a comment

purging hot tub ( air lock )

purging your hot tub ( refilling your tub , flo error , pump runs,but no water circulation, )

When refilling your hot tub after a winterization , or drain and clean, you may experience an airlock in your hot tub system. its just the law of physics at work here so there is no major component fault. tell-tale signs is the hot tub circ pump or pump (jets ) number one on your hot tub is running but there is no water flo or movement in the tub and the top side error codes Flo, three dots,dry may appear depending on your make and model of hot tub. The best way to take care of the issue is to read the manual of your hot tub for specific purging procedure as some are partial automatic and others tell u where to find the purge srews to let the air out. note: it is always best to fill the hot tub thru the hot tub canister to help reduce air locks.
caution: hot tubs carry high voltage and guide below works with general systems so if your not sure best to hire a hot tub tech.
(so no luck with the hot tub manual )
guide ( 1st try )
1. turn off the power to your hot tub
2. take the filter out of the hot tub and place your garden hose in the canister right to the bottom inlet and turn on the water high. this may force the water to push out the air in the system. ( should see bubbles coming out of jets.
3. take hose out and start the hot tub system up
2nd try
1. turn off the power to your hot tub
2. identify your circulation hot tub pump ( this pump feeds the hot tub heater that is a stainless steel tube )
3. loosen the pump union that is attached to the plastic pipe (this connects the pump to the lines) .or loosen the purge valve screw. either way, loosen it just enough for air to rush out ( hissing noise ),. note :the purge nut is on the wet end of the pump faceplate.
4.when hissing stops and water begins to drip out , tighten the nut
5. start up system
you should be on your way to a good night of hot tubing ,but if your still having trouble, give us a call
Posted in Uncategorized | Leave a comment

hot tub error codes

Is Your Spa Hot Tub Jetted tub Pool Not Working Properly? call 587.333.2386

Typical hot tub error codes listed here , however your manual or operation card should have your error codes for your hot tub listed. for more info or repairs required give us a call Cochrane 587-333-2386

other 1-877-440-9378

_ML400Sm-LFwT

ACC systems

CoLd = cold temperature in the hot tub heater housing is below 40° F. Status of the heater element is unknown. The low speed pump or circ pump will operate continuously until the temperature rises above 45° F.
OH = Over heat in the heater barrel or tub. The hot tub is at a temperature above 108° . Do not use hot tub when temperature is flashing or the OH message is displayed.
HLoH = Hi Limit Over Heat in heater barrel or hot tub. Hi limit sensor may also be disconnected or shorted or the spa temperature is above 112° F.
SEoP = Sensor open or disconnected.  Heater disabled but the hot tub is operational.
SESH = Sensor short, nonfunctional. Heater disabled but the hot tub is operational.
PSoC = Pressure switch open with circulating pump. wire disconect
PSoL = Pressure switch open with low pump.
PSoH = Pressure switch open with high pump.
ToE = Time out error. Rare system error.  Spa unusable. Contact ACC.

for more info or repairs required give us a call

Cochrane  587-333-2386

other cities 1-877-440-9378


Balboa systems  ( m7 and or non m7 )

pd = Power supply, unit running on battery backup
OH = Sensors reading 112-118° F.
OHH = Overheat. hot tub has shut down. One sensor has detected 118º Fat heater.
OHS = Overheat. hot tub has shut down. One sensor has detected 110ºF.
Flo = Improper flow or pressure switch malfunction
Cool = Water temp 20° below set point
ICE = Potential freeze condition has been detected
Sn1 = Hi-limit sensor malfunction
Sn3 = Temp sensor malfunction
SnA = Hot tub is shut down. Sensor plugged into jack A is not working.
Snb = Hot tub is shut down. Sensor plugged into jack B is not working.
SnS = Sensors out of balance. If alternating with temp, may be temporary condition. If display shows only this message (blinking) Hot tub is shut down.
HFL = Substantial difference between temperature sensors detected. Could indicate a flow problem.
LF = Persistent low flow problems. (Displays on the 5th occurrence of “HFL” message with 24 hours).  Heater is shut down, but other hot tub functions run normally.
dr = Inadequate water detected in heater.
dry = Inadequate water detected in heater. (Displays on third occurrence of “dr” message).  Hot tub  is shut down.
Pr = When hot tub is first actuated, it will go into Priming Mode.
ILOC = Interlock failure – possible pump or ozone spike .
(—) =Unknown water temperature. (Displays when first powered up after refill).
Std = Hot tub operating in Standard Mode.
Ecn = Hot Tub operating in Economy Mode.
SE = hot tub operating in Standard-in-Economy Mode.

ST= Hot tub in Standard operating mode

SL= Hot tub in sleep mode

for more info or repairs required give us a call at

Cochrane 587-333-2386

other cities 1-877-440-9378


Brett Aqualine

OH = Temp exceeds 118° F
Fr = Freeze condition – temp below 40° F
FL = Pressure switch failure
EO = Shorted temp sensor
E1 = Open temp sensor
E2 = Shorted hi-limit sensor
E3 = Open hi-limit sensor
E4 = Shorted flow switch
E7 = Improper electrical connection

for more info or repairs required give us a call

Cochrane 587-333-2386

other cities 1-877-440-9378


CTI

th1/39 = On startup indicates temperature probe problem.
th2/current temperature = On startup indicates temperature probe problem.
th3/39 = On startup indicates water temperature less than 39° F.
OH = Overheating, water over 112° F. System will restart when temp. drops.
hot = Overheating, water over 112° F. System will restart when temp. drops.
HL = High limit switch tripped.

for more info or repairs required give us a call at

Cochrane  587-333-2386

other cities 1-877-440-9378


Dream Maker Hot Tubs

OH = Overheat 108° F, spa is deactivated. Do not enter the water.
FL = Flow. Pressure switch is not working.
SN = Non functional high temperature sensor.  Heater is deactivated.
F2 = 4 hours daily filtration
F4 = 8 hours daily filtration
F6 = 12 hours daily filtration
FC = continuous filtration

for more info or repairs required give us a call

Cochrane   587-333-2386

other cities 1-877-440-9378


EasyPak

C = Celsius
CL = Current Time of Day
ECdu = Economy Mode Duration
Econ = Economy Mode Turn On
F = Fahrenheit
Fldu = Filter Cycle Duration
Flon = Filter Cycle Turn On
FLC = Pressure Switch Alarm
FLO = Pressure Switch Alarm
FrEE = Freeze Protection Alarm
HL = High Temperature Alarm
Loc = Panel / Keypad Locked
PrH = Temperature Sensors Alarm
Prr = Temperature Sensors Alarm
Tu = Temperature Set Celsius
Tu = Temperature Set Fahrenheit

for more info or repairs required give us a call

Cochrane   587-333-2386

other cities 1-877-440-9378


Gecko

…     = Pressure switch failure or low flo condition

FLO = Pressure switch failure, or low flo condition

FLC = Pressure switch failure, switch closed
Prr = Temp sensor failure
Prh = Hi-limit sensor failure
HL = Sensor measuring 119° F
FrE = Possible freeze condition detected

for more info or repairs required give us a call

Cochrane    587-333-2386

other cities 1-877-440-9378


Hercules

OH = hot tub temp exceeds acceptable limits
FLO = Flow problem
ICE = Freeze condition detected
SN1 = Hi-limit sensor failure
SN2 = Temp sensor failure

for more info or repairs required give us a call

Cochrane   587-333-2386

other cities 1-877-440-9378


Hurricane

PS = Flow or pressure switch failure
SH = Shorted sensor
OP = Open Sensor
LO = Temp below 60° F – freeze
HL = Temp above 118° F

for more info or repairs required give us a call

Cochrane    587-333-2386

other cities 1-877-440-9378


Hydro-Quip

C = Celsius
CL = Current Time of Day
ECdu = Economy Mode Duration
Econ = Economy Mode Turn On
F = Fahrenheit
Fldu = Filter Cycle Duration
Flon = Filter Cycle Turn On
FLC = Pressure Switch Alarm
FLO = Pressure Switch Alarm
FrEE = Freeze Protection Alarm
HL = High Temperature Alarm
Loc = Panel / Keypad Locked
PrH = Temperature Sensors Alarm
Prr = Temperature Sensors Alarm
Tu = Temperature Set Celsius
Tu = Temperature Set Fahrenheit

for more info or repairs required give us a call

Cochrane   587-333-2386

other cities 1-877-440-9378


Jacuzzi Whirlpool

OH = Overheat Protection (Heater is deactivated, pumps low speed is activated).
COOL = hot tub water is more than 20° F cooler than the temperature set point.
FLO* = Flow Switch (heater is deactivated. Pump may also be deactivated).
Hold = Panel sensors have been pressed too many times in a short period of time.
HOT = Circuit Board temperature has exceeded acceptable limit.
ICE = Freeze protection.  No action is necessary.
I CE2 =  Freeze protection.  No action is necessary.
PnL = Communication between the panel and circuit board is faulty.
—- = “Watchdog” (hot tub is deactivated) A problem has been detected.
Sn1 = Open sensor (heater is deactivated) or  Shorted sensor (hot tub is deactivated).
Sn3 = Open or shorted sensor ( heater disabled).
FLO2 = Closed or shorted flow switch on system startup

for more info or repairs required give us a call

Cochrane    587-333-2386

other cities 1-877-440-9378


Pinnacle

OH = Temperature has exceeded 110° F
SN = Sensor failure
FL = Flow/pressure switch stuck in closed position

for more info or repairs required give us a call

cochrane      587-333-2386

other cities 1-877-440-9378


Spa Builders

Sn1 = Nonfunctional high temperature sensor. Heater is deactivated.
Sn2 = Nonfunctional temperature sensor. Heater is deactivated.
FL1 = Water flow problem, inhibited or pressure switch malfunction. Check for proper hottub water level and ensure pump is primed. Check for clogged filter.
FL2 = Pressure switch problem. Switch closed while pump is deactivated.
COL = Cool condition. If water temperature drops 20ºF below set temperature, low speed pump and heater activates to bring temperature within 15º of set temperature.
ICE = Freeze condition. 55ºF detected. Low speed pump and heater will activate until hottub reaches 65ºF.
OH = High temperature condition, has reached 110ºF. Do not enter the hot tub. Low speed pump (and air blower if so equipped) will activate to assist in lowering temperature.
 = “Watchdog”.  Water temperature has reached 118ºF. Entire system is disabled.  Contact qualified service technician.

for more info or repairs required give us a call

Cochrane     587-333-2386

other cities 1-877-440-9378


Sundance Spas

ILOC = Interlock failure – possible pump or ozone spike
FLO = Pressure switch malfunction or Flow switch malfunction (system specific)
Hold = Panel buttons pressed to many times to quickly
HOT = PCB temperature above acceptable limit – air blower on
ICE = Potential freeze condition
Pnl = Communication between PCB and panel interrupted
Sn1 = Hi-limit sensor failure
Sn3 = Temp sensor failure
—- = “Watchdog” (hot tub is deactivated) A problem has been detected

for more info or repairs required give us a call

Cochrane     587-333-2386

other cities 1-877-440-9378


Vita Spas

HiLi = Water temp over acceptable limit
BJ2P = Pump/Blower purge – normal condition
FP = Freeze protect-temp under acceptable condition
SS=0; SS=S; LS=O; LS=S = Multiple causes; open sensors, bad connection to panel, improper voltage, etc.

for more info or repairs required give us a call

Cochrane   587-333-2386

other cities 1-877-440-9378

Posted in Uncategorized | Leave a comment

How to know if a hot tub heater is not working

How to know if a hot tub heater is not working.  587-333-2386

Their are many reasons why a hot tub may stop heating, the following points define the most common not heating reasons. Sometimes 2 or more of the following problems have to be resolved to resume heating in a hot tub.

Dirty filters ( #1 )

Very common finding in visits with hot tub flow and heating issues.

dirty hot tub filters, try replacing the filter for a new one and see if this resolves your problem, if the filter is more than 1 years old it will probably need changing anyway.

we have all your filters . give us a call   587-333-2386

Pressure switch

Most hot tub heaters (apart from Balboa M7 Heaters) have a pressure switch which proves water is flowing inside the hot tubs plumbing, when the circulation pump of the spa starts up the pressure from the pump will close a circuit which enables the power for the hot tub heater.

This can get blocked or may need replacing, the control panel will usually define this with an error code: FL1 FLO or 3 lines or dots (— or . . .) .

(note: never adjust a pressure switch, they are factory set and designed to fail, if the switch stays open and the circulation pump fails you will get an expensive repair bill)

we have pressure switches for all makes and brands. give us a call for parts and installation.  587-333-2386

Faulty Circulation Pump

Faulty hot tub pumps are common, the reduced flow of a dirty filter can easily burn out a hot tub pump, If the pump is getting power and roatating it may just be an air lock (try lossening a pump union to resolve or  purge nipple on face plate). should hear a hissing noise followed by water trickle.

If the pump is buzzing the capacitor,  burnt out coil and rusty/ seized bearings may need be the reason.

call us for pumps and installation  587-333-2386

Heater Tripping Hot Tub

g.f.i tripping outright

Reasons for tripping hot tub heaters:

Hot tub filled with water incorrectly – if the water is filled through the middle and not through the filter housing to push air out, it will burn out.

Incorrect chemicals – Swimming pool chemicals and highly aciddic water will burn out the seals on a hot tub heater. (swimming pool/ cheap chemicals will also burn out pump seals and anything else made of rubber.)

at western we provide free chemical advice and only quality chemicals made for hot tubs. give us a call with your hot tub chemistry concerns.

Incorrectly fitted hot tub  heater elements – Get a hot tub technician to replace your heater instead of the local neighbourhood handyman

Blockages – plastic parts and foreign parts in the hot tub will burn out heater elements.

Burn’t Out Circuit Boards or PCB’S

Sometimes if a fault has been happening for a while it will put a strain onto the hot tub Circuit Board (PCB) this could mean that a relay has burnt out or stuck. at this stage only a technician should test and service the hot tub.

Posted in Uncategorized | Leave a comment